Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13636148

- Product Categories
- Friendly Links
Information Name: | Siemens soft starter 3RW3014-2BB04 |
Published: | 2015-01-19 |
Validity: | 30 |
Specifications: | 11 |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | Siemens standard soft starter for electrical machinery requires soft start and / or soft stop applications. Siemens offers a variety of devices for this purpose:? SIRIUS 3RW30 / 31 - a low cost solution - for motors rated up to 55 kW - the components can be combined with the SIRIUS SIRIUS 3RW40 - using an extremely compact design - fits the motor? ratings up to 250 kW - can be carried out with a combination of components SIEMENS SIRIUS German authorized dealers Shanghai agent professional agent Siemens CNC servo, spare parts and special discontinued models, only you can not think, no we can not do!! Fair price, product warranty for one year! 7 days can be returned! Shanghai Yun Chi practice stand in line to use the letter on the package you spend a lifetime with Siemens Contact: Wu Changsheng (Mr.) Tel: 021-61849405 Mobile: 18659609059 Fax: 021-3778450 e-mail: 596280525@QQ.com Business QQ: 596 280 525 Answers for their second. Market number (order): Siemens soft starter 3RW3014-2BB04 Details: SIRIUS soft starters -S00 specifications, 6.5A, 1.5KW / 400V, 40 ° C, AC 200-480V, AC / DC 24V, spring terminals SIRIUS 3RW30 soft starters through a variable phase control reduces the motor voltage, and rise from the beginning of selectable voltage ramp mode to the power supply voltage. When starting, these devices limit the torque and current, and prevents direct starting or star - shock generated when the delta starter. Thus, the mechanical load and the power supply voltage drop can be reduced reliably. Soft-start reduces the stress connected devices, reducing wear and tear, and therefore no longer trouble-free production. The optional start value means that the soft starter can be individually adjusted to the needs of the application in question, and not the star - delta starter in two stages with a fixed limit voltage ratio starts. SIRIUS 3RW30 soft starter at small space requirements for having outstanding features. Integrated bypass contacts mean that after the motor starter, in the transaction without regard to the power semiconductors (SCR) power consumption. Thus reducing heat loss, making the design more compact, and no external bypass circuit. Offers a variety of models of SIRIUS 3RW30 soft starters:? The standard model for fixed-speed three-phase motor, standard S00, S0, S2 and S3, with integrated bypass contact system models for fixed-speed 22.5 mm housing three? phase motor, no bypass starter rated power of 55 kW (400 V), can be used for standard applications in three-phase grid. Which soft starter with a small size, low power consumption and ease of debugging. Contact space functional compact SIRIUS 3RW30 soft starter is only required to compare ratings wye-delta starters third of the space required. This not only saves space in control cabinets and standard mounting rails, but also completely eliminates the wye-delta starter wiring work required. This is particularly evident for high motor ratings, these high ratings rarely used as a high-tech solution. At the same time, connect the starter motor cable and the required reduced from six to three. Compact dimensions, short start-up time, simple wiring and fast commissioning make soft starter has a significant cost advantage. These soft starter bypass contacts at work by an integrated solid-state arc system protection. Thereby preventing damage to the bypass contact when a fault, such as a coil spring operating mechanism or the main operation of the control voltage transient failure, mechanical shock or the defective part associated with life. The new device series with "polarity balancing" control method for the protection of two-phase controlled soft starter in DC components. For two-phase controlled soft starters, two control phases overlap current flows from uncontrolled phase. This also leads to physical cause motor soft starters in three-phase current asymmetric distribution. Although this is not affected, but in most applications still can not be ignored. Control not only leads to an asymmetric power semiconductors, when the starting voltage is less than 50% of the motor starting voltage value, the DC component also led to the previously mentioned serious noise. The control method used for these soft starters eliminates the DC component of the soft starter phase and prevents the braking torque that may arise. This method creates speed, torque and current rise on the same motor soft starters, enabling ease the two-phase motor starter. Meanwhile, the start-up operation of the three-phase control sound quality close to the soft starter. Can be achieved by the motor during the soft-start different polarity half-wave current ongoing dynamic coordination and balance. Hence the name "polarity balancing." ? Voltage ramp soft start; starting voltage adjustment range Us is 40-100%, ramp time tR of 0s ~ 20s. ? Integrated bypass contact system to minimize power loss? Using two potentiometers set? Simple installation and commissioning? Supply voltage 50/60 Hz, 200 ~ 480 V? Two control voltage Model 24 V AC / DC and 110 -?? 230 V AC / DC wide temperature range, from -25 ~ +60 ℃ built-in auxiliary contacts ensure user-friendly controls, and can be further processed in the system. 3RW30 soft starter can be used for three-phase induction motor soft starters. As the two-phase control, throughout the start-up time, the current in each phase is always kept at a minimum. Due to continuous voltage impact, the star - delta starter under conditions of inevitable phenomena, such as current and torque peaks, in this case does not occur. Applications? Pump? Pump? Pump? Press? Conveyors? Roller conveyor? Screw conveyor Auswahlhilfe für Sanftstarter 3RW + Randbedingungen More information 3RW solid-state motor controller configuration is designed for easy start condition. Under abnormal conditions or increasing the switching frequency of the case, it may be necessary to choose a larger device. If the start time is longer, if necessary, must be selected for the start load of heavy overload relay. Recommend using PTC sensor is not allowed in the motor feeder using a capacitive element (eg, you can not use reactive power compensation equipment) between SIRIUS 3RW soft starter and the motor. In addition, both the static system for reactive power compensation, or dynamic PFC (power factor correction), at the start-up and ramp-down of the soft starter can not be operated in parallel. This is to prevent compensation equipment and / or soft starter failure is very important. All elements of the main circuit (for example fuses, switching devices and overload relays) should be loaded in accordance with the case of a short circuit at the start of the corresponding directly for selection. Fuses, switching devices and overload relays must be ordered separately. Please observe the technical data specified in the maximum switching frequency. Note: When you turn on the induction motor, on all types of starters (direct starter, star - delta starters, soft starters) usually produces a voltage drop. Feeder transformer size must be able to achieve this effect: When you start the motor, the voltage drop that occurs not exceed the permitted tolerance range. If the edge of the feeding transformer is dimensioned smaller, it is preferable from a separate circuit (not dependent on the mains voltage) fed to the control voltage, in order to prevent possible soft starter cut case. SIRIUS 3RW soft starter simulation system benefits at a glance:?? Soft start and smooth drop (only 3RW30 soft start function) Promise to start reducing the peak current to avoid when you start to reduce the power supply voltage fluctuations on the grid to reduce the load on the entire operation mechanism???? mechanical loads? Compared to conventional starters, significant savings in space, reducing the wiring? maintenance switch? handle its simplicity? and SIRIUS modular system (3RW30 and 3RW40) perfectly with Siemens industrial energy efficiency can provide a unique management product line to optimize the energy demand. Siemens Energy Management will be divided into three phases: identification, assessment and implementation, and at every stage of the energy management process are provided with the appropriate hardware and software solutions. In addition, the new SIRIUS industrial control products also help greatly improve the energy efficiency of the plant. Use the soft start, the whole, you can bring the following to promote the role of the factory can:?? Energy Management provides services such as current, voltage and power (3RW44), etc. through the bus, the upper computer data current energy management system to avoid current peak, therefore, reduce the load on the grid and mechanical systems? lower control cabinet temperature rise according to its technical characteristics, can be obtained compared with the variable speed drive systems lower internal consumption, thus, lower cooling requirements, you can achieve a more compact design. All specifications are equipped with bypass protection functions, enabling lower power consumption after startup. SIRIUS 3RW soft starters through SIRIUS 3RW soft starter, soft start and enables smooth deceleration phase asynchronous motors. According to the functional scope, can be selected as follows:??? For standard applications for high-performance applications soft starter soft starter SIRIUS 3RW - been proven in many applications run SIRIUS soft starter features include: - Soft Start and smooth drop (only 3RW30 soft start function) - Promise start - torque control and limit cost-effective operation of SIRIUS soft starters advantages at a glance: reduce current peak supply voltage fluctuations to avoid when you start to reduce the load on the grid????? reduce the mechanical load the entire operating mechanism? Compared to conventional starters, significant savings in space, reducing the wiring? maintenance switch? handle its simplicity? and SIRIUS modular system (3RW30 and 3RW40) perfectly with SIRIUS 3RF solid-state switch solid state device SIRIUS 3RF2 breaking device can reliably breaking 50 Hz and 60 Hz systems are widely AC load. Activities SIRIUS 3RF2 solid-state switching devices for resistive load? Solid state relay? Solid State Contactor? Function module is used to switch the motor SIRIUS 3RF3 solid-state switching devices? Solid State Contactor? Solid state reversing contactors SIRIUS 3RF2- for almost no termination conventional electromechanical switching devices due to increased number of switching operations are heavily taxed families. The switching frequency is too high leads to frequent breakdowns and replacement cycle is shorter. However, this situation is also a non-static, because with our latest generation of solid-state switching devices SIRIUS 3RF2, we provide you with a solid-state relays and contactors, particularly long service life - can be used under the most difficult conditions of almost non-stop activities, as well as In the case of high mechanical load, but also can be used for noise-sensitive areas. SIRIUS 3RF2 proven repeatedly proven solid-state switching devices in industrial applications has been firmly occupy a place. But the most important thing in frequent switching loads of occasions - mainly used in transmission systems resistive load controllers, control or control valves and electric motors. SIRIUS breaking very quiet, except for use in areas with a higher frequency of breaking, but also very suitable for use in noise-sensitive areas (office or hospital). Suitable for a variety of applications, most reliable solutions and mechanical switching devices compared to our solid-state switching devices SIRIUS 3RF2 due to longer life and became more prominent. Due to the high product quality, the switch very accurate, reliable, and most importantly, is not prone to failure. With its ever-changing connection methods and broader control voltage, SIRIUS 3RF2 series has been popular around the world. Depending on the requirements of the application, our modular switching device also may be very easily be extended by adding standardized function modules. Applicable to heating control systems, for example, may be 3RF2 solid state switching means in SIPLUS HCS 300i heating control used in the system. Under the best case, you can use pre-assembled cables to connect them to the HCS 300i digital output module. This saves a lot of control circuit wiring costs and shorten the installation time. HCS 300i is a modular plastic processing equipment for optimizing heating control system. It is realized by heating control applications for many different solutions. Can be up to four six-channel digital output by each basic unit used to control solid state switching elements and four 4-channel temperature measurement module. May use current or current / voltage measurement module to monitor the load measurement. PC control system communications and is done by Profibus DP. Can also be used to switch the motor in order to achieve higher productivity, the switching frequency of the need to constantly improve. This is for our SIRIUS solid-state contactors to switch the motor run without problems. With power up to 7.5 kW induction motor, they can always withstand even the highest switching frequency. Solid state reversing contactor, even constantly changing the direction of rotation. Both models are modular systems and components SIRIUS perfect combination. Without any additional steps can and SIRIUS SIRIUS motor starter or overload relay connections. SIRIUS SC allows you to confidently because SIRIUS 3RF2 can offer more:? Save space and compact side suffer side mounting ensures reliable operation in ambient temperatures of +60 ° C. ? Due to the rapid configuration and easy installation and start-up, you can save time and effort. Connection provides a soft starter with screw-type terminals or spring-type terminals. These solid-state switching devices in the use of screw-type terminals (cassette terminals), spring-type terminals or ring terminal connector. More information is integrated into the load feeder Notes due to its industrial connection method and design, SIRIUS solid-state switching devices can easily be integrated into the load feeders. However, still need to pay particular attention to the installation and environmental conditions, because the performance of solid-state devices open turn relies heavily on the above conditions. Depending on the model, you must comply with some restrictions. For more information about the solid-state contactors and solid-state relay radiator minimum interval selection can be found in the technical specifications and product data sheets. Despite the short-circuit and overload protection used in power semiconductor design firm, solid-state switching devices for load feeders still short reaction is very sensitive. Therefore, according to the type of design remains particularly vigilant damaged. Siemens is generally recommended to use SITOR semiconductor fuses. Even when the solid-state contactors and solid-state relays take full advantage of these fuses can still provide protection against damage. That is, if the load is low, the standard fuse or miniature circuit breakers can also provide protection. Correspondingly increased by a solid-state switching devices to achieve the purpose of protection. Technical specifications and product data sheets, including their own protection as well as details on the use of solid-state devices with conventional fuse protection apparatus. Semiconductor motor and reversing contacts can be easily and SIRIUS modular system 3RV motor starter protector and 3RB2 overload relay combination. Thus, the motor feeders with fuses and no fuses can easily design and save space. Electromagnetic compatibility (EMC) solid-state switching device is suitable for interference-free operation in industrial networks without additional measures. If used in a public network, you need to use a filter to reduce conducted interference. This does not include 3RF23 ..-. CA .. "Low Noise" special model, the solid-state contactors for resistive loads. This is consistent with B-pole 16A maximum limits. If you use other models in the current greater than 16 A in the next, you can use the standard filter to comply with the limits. The decisive factor in selection filter main feeder load current load and other parameters (voltage and design type, etc.). |
Admin>>>
You are the 8866 visitor
Copyright © GuangDong ICP No. 10089450, Shanghai Yun Chi Industrial Equipment Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8866 visitor
Copyright © GuangDong ICP No. 10089450, Shanghai Yun Chi Industrial Equipment Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility