Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13636148

- Product Categories
- Friendly Links
Information Name: | Siemens touch screen 6AV6 642-0BA01-1AX1 |
Published: | 2015-01-14 |
Validity: | 30 |
Specifications: | 11 |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | SIEMENS Germany authorized dealers Shanghai an agent Agency Siemens CNC servo, and discontinued spare parts! Special models, only you can not think, no we can not do! Fair price, product warranty for one year! 7 days can be returned! Shanghai Yun Chi practice stand in line to use the letter on the package you spend a lifetime with Siemens Contact: Wu Changsheng (Mr.) Tel: 021-61849405 Mobile: 18659609059 Fax: 021-3778450 e-mail: 596280525@QQ.com Business QQ: 596 280 525 Answers for their second. Market number (order): 6AV6 642-0BA01-1AX1 Artikelnummer 6AV6642-0BA01-1AX1 SIMATIC touch panel TP177B PN / DP STN 265 color display, MPI / PROFIBUS DP protocol RS485 / RS422 / USB interface, Ethernet 10 / 100M interface, printer interface, MMC memory card slot for WINCC FLEXIBLE 2005 by configuring general user-defined configuration information display screen size STN screen size 5.7 inches diagonal 5.7 in (120 mm x 90 mm) display Screen Type STN, 256-color color type color resolution (pixels) ● Horizontal image resolution 320 ● 240 ● Vertical resolution image resolution (width x height, unit: pixel) 320 x 240 Backlight ● MTBF background lighting (temperature at 25 ° C) 50 000 h operating elements of the touch screen element operable touchscreen mouse / keyboard / barcode reader interface USB / USB / USB keyboard ● ● system key is the digital input and alphabetic input is / was - sixteen ● hexadecimal keyboard is a multi-button operation is not a touch screen ● The touch screen is the voltage of the power supply voltage DC input current type rated current of 0.24 A turn A2s 0.5 A2 · s Processor Type ARM, 200 MHz memory for user data 2 048 kbyte memory available ● Type hardware clock time clock can be synchronized, unbuffered ● Hardware clock (real-time clock) is a software clock is not ● ● ● You can not synchronize the cache is optional RS232 interface port, 1 x RS422,1 x RS485,1 x Ethernet (RJ45) (maximum 12 MBit / s) RS 485 interface number 1 ● transmission rate, maximum 12 Mbit / s USB connector 1 x USB PC card slot No CF card slot No Multi Media Card / SD card slot is a combination, E-Stand 016 above in connection with WinCC flexible 2008 SP1, MMC maximum 128 MB / SD 512 MB maximum special interface No Industrial Ethernet ● Industrial Ethernet interface 1 x Ethernet (RJ45) ● Industrial Ethernet status LED a protocol agreement (terminal connection) ● Sm @ rtService is the protection and positive protection category IP65, NEMA 4x, NEMA 12 (in the installed state) IP (front) IP65 IP (backside) IP20 standards, licensing, certification CE certificate , GL, ABS, BV, DNV, LRS, FM Class I Div. 2, UL, CSA, cULus, EX-Zone 2, EX-Zone 22, C-TICK, NEMA 4x, NEMA 12 cULus is the EAC (Gost- R format) does not apply to the safety features of ship construction permit ● Germanischer Lloyd (GL) is the ● US Ship Inspection Bureau (ABS) is a ● will Veritas (BV) is a Norwegian ship classification ● Agency (DNV) is a ● Lloyds Register of Shipping (LRS) is a ● Polish Register of Shipping (PRS) is not in use ● explosion hazardous areas Zone 2 hazardous areas ● Yes 22 Yes ● FM Class I 2 is the environment requires the installation position vertical maximum permissible angle of inclination without external ventilation of +/- 35 ° Storage / transport temperature ● transport, storage -20 ° C to +60 ° C ● Operating relative humidity, maximum 90% of an operating system Windows CE system configuration message is displayed with the message is in the process systems (including buffer and transponder) is the value display (output) is a process value can be specified (input) is the program management is configuration software ● STEP 7 Basic (TIA Portal) without ● STEP 7 Professional (TIA Portal) without ● WinCC flexible Compact ● WinCC flexible Standard Yes Yes Yes ● WinCC flexible Advanced ● WinCC Basic (TIA Portal) without ● WinCC Comfort (TIA Portal) is The ● WinCC Advanced (TIA Portal) Yes ● WinCC Professional (TIA Portal) ● The configuration tool is more than 2005 versions of WinCC flexible Compact (individual involved) ● 2. configuration package WinCC flexible Compact - Version 2005 - Configuration Tools WinCC flexible - Type Compact Languages ??Online languages ??● functional language 32 WinCC online / runtime languages ??5 Languages ??● amount under each project (TIA Portal) library is a mission plan is to help system is ● Each message text The number of characters in the message system 70 32 ● ● Message number of classes the number of messages 2 000 ● ● Analog bit message is a message that the number of messages ● bit analog message number 2 000 ● 50 ● S alarm message transmission method is not ● System messages HMI The ● PLC system message is the system message ● more (SIMATIC S7, Sinumerik, Simotion ...) not ● message length (unit: character) 80 ● 1 ● Line process values ??each message number 8 ● 99 ● Acknowledgement group ● The message indicator is not audible feedback ● first / last value is the number of program management ● 100 ● Each recipe recipe data entry for each data set 200 ● 200 ● set formula 32 kb integrated flash memory can be ● Extended variable number of variables per device 1 000 ● variable number of each image 50 ● the number of variables 1 000 ● Initial value threshold is 1 000 ●. ●. ● multiplexing structure is not the date and time ● Type 1 000 screen ● configurable number of images 500 ● permanent window / default Yes ● configurable boot image is a selection via the PLC ● ● PLC in the image is the image number is the picture objects ● Text objects 2500 text elements ● Each image domain 50 ● Date / time field 30 ● ● image content directory does not jump back Yes ● graphic objects bitmaps, icons, icon (full screen), Vector - Icon 500-- Icon (full screen) 50 complex Picture Object ● Status / Control ● SIMATIC S7 dynamic objects in graphs, bar charts, slides, analog display, hidden button - the number of objects in each project 500 - Number of each image to 5 ● ● critical value method ● Each line is a picture of the number of spokes 5 ● ● The critical value of the line is an alphanumeric field 1 000 ● Each image alphanumeric fields 100 ● Digital Domain 1 000 ● each image in the digital domain 100 ● password field 1000 ● increase the number of images per scrollbar 0 ● simulation of each image shows the number 0 ● visible switches per item 1 000 ● Number of visible switches per image per image 100 ● invisible switch 100 ● each project state switch number 1 000 ● status of each image switch button 100 ● select switches per item 1 000 ● Decimal number of switches per image selection switch 100 ● 0 ● each project each image decimal switch 0 ● Each indicator is the number of items 1 000 ● Properties ● color change indicator 100 for each image. ● dynamic objects are moving X / Y Yes Yes ● ● Hidden List ● Text rotation angle does not list the number of each item 300 ● text lists the number of each image 10 ● The number of entries per text list of 30 ● graphic lists the number of each item number 100 ● graphic list of each image 10 ● graphic lists the number of entries for each 30 Security ● Users The number of groups 50 ● number of users permission 32 ● Password export / import is the data transfer support ● PC card is not ● CF card without going through a printer recording ● Record / print news reports (layer protocol), color print, hardcopy Transfer (upload / download ) ● Transfer the configuration MPI / PROFIBUS DP, serial, USB, Ethernet, by means of an external storage medium, automatic identification of the transmission process connection ● connected to the controller S5, S7-200, S7- 300/400, Win AC, PC ( TCP / IP), SINUMERIK, SIMOTION, AllenBradley (DF1), Mitsubishi (FX), Telemecanique (ADJUST), Modicon (Modbus), more external drivers, see chapter "System Coupling" ● S7-1200 Yes ● S7-1500 ● S7-200 is not a - PPI (Point to Point) Yes - PPI network is not - MPI Yes - PROFIBUS DP Yes - Ethernet yes yes ● S7- 300/400 - MPI Yes - PROFIBUS DP Yes - ● S5 PROFINET Yes Yes; only PROFIBUS DP - Serial no - PROFIBUS DP Yes ● TI 505 not ● Allen Bradley (DF1) Yes ● Allen Bradley (DF485) Yes ● Mitsubishi (FX) is the ● Telemecanique ( ADJUST) not ● Telemecanique (Uni-Telway) Yes; only when using the WinCC flexible ● OMRON (LINK / Multilink) Yes ● Modicon (Modbus) is not a function ● ● TAB key repeat order is the calculation function ● Yes ● ● animation is a menu tree editor is not ● The unit switches service tools / configuration tools ● ● clear the screen is a touch calibration Yes ● Backup / restore Yes Yes ● ● analog conversion equipment Yes ● Incremental transfer Yes ● monitors the battery and memory functions are not ● Trace (operation archive) non-scalable / open ● Open Platform program is a peripheral / Options Peripherals ● multimedia card is add-on software components that can be loaded is the size of the shell front width 212 mm height 156 mm front casing installation section / device depth (W x H x D) 198 mm x 142 mm / 44 mm device depth Weight Weight (without packaging) 0.8 kg other free hotline Yes Warranty period 1 y |
Admin>>>
You are the 8866 visitor
Copyright © GuangDong ICP No. 10089450, Shanghai Yun Chi Industrial Equipment Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8866 visitor
Copyright © GuangDong ICP No. 10089450, Shanghai Yun Chi Industrial Equipment Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility